SUNNY CENTRAL 800CP XT / 850CP XT / 900CP XT
The extended CP XT: peak output up to 1 megawatt
- Max. permissible DC voltage: 1000 V
- Nominal AC power (@ 50 °C): 800 kVA / 850 kVA / 900 kVA
More power: With its extended functions, the new Sunny Central CP XT series is now even more efficient. The reduced specific price, mean that maximum yields are achieved with lower system costs. The Sunny Central CP XT is also optimized for cold temperatures down to -40 °C and with full nominal power in continuous operation up to 50 °C. The inverter includes all grid management functions and is prepared for Q-on-demand. The customized computer platform allows for optimal monitoring and control.
Profitable |
Durable |
Flexible |
Versatile |
• Up to 1 megawatt system power as standard • Significantly reduced specific price thanks to increased power • Maximum yields with low system costs |
• Full nominal power in continuous operation at ambient temperatures up to 50 °C • Optimized for extreme climatic con- ditions between −40 °C and 62 °C • Active temperature management |
• Wide DC input voltage range for flexible use of various module configurations • Perfectly adjusted for the tempe- rature-dependent behavior of PV arrays |
• All grid management functions are included, prepared for “Q at Night” including pure reactive power operation • Customized computer platform for optimal monitoring and control of |
Technical Data |
Sunny Central 800CP XT |
Sunny Central 850CP XT |
Input (DC)
Max. DC power (at cos φ =1) |
898 kW |
954 kW |
Max. input voltage |
1000 V |
1000 V |
VMPP_min at IMPP < IDCmax |
530 V |
568 V |
MPP voltage range (at 25°C / at 50°C at 50 Hz)1) 2) |
641 V to 850 V3) / 583 to 850 V3) |
681 V to 850 V3) / 625 to 850 V3) |
MPP voltage range (at 25°C / at 50°C at 60 Hz)1) 2) |
641 V to 850 V3) / 583 to 850 V3) |
681 V to 850 V3) / 625 to 850 V3) |
Rated input voltage |
641 V |
681 V |
Max. input current |
1400 A |
1400 A |
Max. DC short-circuit current |
2500 A |
2500 A |
Number of independent MPP inputs |
1 |
1 |
Number of DC inputs |
9 |
9 |
Output (AC)
Rated power (at 25°C) / nominal AC power (at 50°C) |
880 kVA / 800 kVA |
935 kVA / 850 kVA |
Nominal AC voltage / nominal AC voltage range |
360 V / 324 V to 414 V |
386 V / 348 V to 443 V |
AC power frequency / range |
50 Hz, 60 Hz / 47 Hz to 63 Hz |
50 Hz, 60 Hz / 47 Hz to 63 Hz |
Rated power frequency / rated grid voltage |
50 Hz / 360 V |
50 Hz / 386 V |
Max. output current / max. total harmonic distortion |
1411 A / 0.03 |
1411 A / 0.03 |
Power factor at rated power / displacement power factor adjustable |
1 / 0.9 leading to 0.9 lagging |
|
Feed-in phases / connection phases |
3 / 3 |
3 / 3 |
Efficiency4)
Max. efficiency / European efficiency / CEC efficiency |
98.6% / 98.4% / 98.5% |
98.6% / 98.4% / 98.5% |
Protective devices
Input-side disconnection device |
Motor-driven load-break switch |
Motor-driven load-break switch |
Output-side disconnection device |
AC circuit breaker |
AC circuit breaker |
DC overvoltage protection |
Type I surge arrester |
Type I surge arrester |
Lightning protection (according to IEC 62305-1) |
Lightning Protection Level III |
Lightning Protection Level III |
Stand-alone grid detection active / passive |
● / — |
● / — |
Grid monitoring |
● |
● |
Ground fault monitoring / remote-controlled ground fault monitoring |
○ / ○ |
○ / ○ |
Insulation monitoring |
○ |
○ |
Surge arrester for auxiliary power supply |
● |
● |
Protection class (according to IEC 62109-1) / overvoltage category (according to IEC 60664-1) |
I / III |
I / III |
General data
Dimensions (W / H / D) |
2562 / 2272 / 956 mm (101 / 89 / 38 inches) |
|
Weight in kg |
1900 kg / 4200 lb |
1900 kg / 4200 lb |
Operating temperature range |
−25°C to +62°C / −13°F to +144°F |
|
Extended operating temperature range |
○ (−40°C to 62°C / −40°F to 144°F) |
|
Noise emission5) |
64 dB(A) |
63 dB(A) |
Max. self-consumption (operation)6) / self-consumption (night) |
1950 W / < 100 W |
1950 W / < 100 W |
External auxiliary supply voltage |
230 V / 400 V (3 / N / PE) |
230 V / 400 V (3 / N / PE) |
Cooling concept |
OptiCool |
OptiCool |
Degree of protection: electronics / connection area (according to IEC 60529) / according to IEC 60721-3-4 |
IP54 / IP43 / 4C2, 4S2 |
IP54 / IP43 / 4C2, 4S2 |
Application in unprotected outdoor environments / indoor |
● / ○ |
● / ○ |
Maximum permissible value for relative humidity (non-condensing) |
15% to 95% |
15% to 95% |
Maximum operating altitude above MSL 2000 m / 4000 m |
● / ○ |
● / ○ |
Fresh air consumption (inverter) |
3000 m3/h |
3000 m3/h |
DC connection / AC connection |
Ring terminal lug / ring terminal lug |
|
Display |
HMI touch display |
|
Communication / protocols |
Ethernet (optical fiber optional), Modbus |
|
DC current monitoring (Zone monitoring / String monitoring) |
○ / ○ |
|
SC-COM / Plant monitoring |
● / ○ (via Sunny Portal) |
|
Color enclosure / door / base / roof |
RAL 9016 / 9016 / 7004 / 7004 |
|
Guarantee: 5 / 10 / 15 / 20 years |
● / ○ / ○ / ○ |
|
Configurable grid management functions |
Power reduction, reactive power setpoint, dynamic grid support (e.g. LVRT) |
|
Certificates and approvals (more available on request)
● Standard features ○ Optional features — Not available |
EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, BDEW-MSRL / FGW / TR8, Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007, P.O. 12.3 / IEEE 15477) |
|
Type designation |
SC 800CP-10 |
SC 850CP-10 |
- At 1.05 UAC, nom and cos φ = 1
- Further AC voltages, DC voltages and power classes can be configured (for more detailed information, see technical information at SMA.de)
- up to 950 V on request
- Efficiency measured without internal power supply
- Sound pressure level at a distance of 10 m
- Self-consumption at rated operation
- Designed and type-tested in accordance with IEEE 1547, serial tests optional available
Technical Data |
Sunny Central 900CP XT |
Input (DC)
Max. DC power (at cos φ =1) |
1010 kW |
Max. input voltage |
1000 V |
VMPP_min at IMPP < IDCmax |
596 V |
MPP voltage range (at 25°C / at 50°C at 50 Hz)1) 2) |
722 V to 850 V3) / 656 V to 850 V3) |
MPP voltage range (at 25°C / at 50°C at 60 Hz)1) 2) |
722 V to 850 V3) / 656 V to 850 V3) |
Rated input voltage |
722 V |
Max. input current |
1400 A |
Max. DC short-circuit current |
2500 A |
Number of independent MPP inputs |
1 |
Number of DC inputs |
9 |
Output (AC)
Rated power (at 25°C) / nominal AC power (at 50°C) |
990 kVA / 900 kVA |
Nominal AC voltage / nominal AC voltage range |
405 V / 365 V to 465 V |
AC power frequency / range |
50 Hz, 60 Hz / 47 Hz to 63 Hz |
Rated power frequency / rated grid voltage |
50 Hz / 405 V |
Max. output current / max. total harmonic distortion |
1411 A / 0.03 |
Power factor at rated power / displacement power factor adjustable |
1 / 0.9 leading to 0.9 lagging |
Feed-in phases / connection phases |
3 / 3 |
Efficiency4)
Max. efficiency / European efficiency / CEC efficiency |
98.6% / 98.4% / 98.5% |
Protective devices
Input-side disconnection device |
Motor-driven load-break switch |
Output-side disconnection device |
AC circuit breaker |
DC overvoltage protection |
Type I surge arrester |
Lightning protection (according to IEC 62305-1) |
Lightning Protection Level III |
Stand-alone grid detection active / passive |
● / — |
Grid monitoring |
● |
Ground fault monitoring / remote-controlled ground fault monitoring |
○ / ○ |
Insulation monitoring |
○ |
Surge arrester for auxiliary power supply |
● |
Protection class (according to IEC 62109-1) / overvoltage category (according to IEC 60664-1) |
I / III |
General data
Dimensions (W / H / D) |
2562 / 2272 / 956 mm (101 / 89 / 38 inches) |
Weight in kg |
1900 kg / 4200 lb |
Operating temperature range |
−25°C to 62°C / −13°F to 144°F |
Extended operating temperature range |
○ (−40°C to 62°C / −40°F to 144°F) |
Noise emission5) |
64 db(A) |
Max. self-consumption (operation)6) / self-consumption (night) |
1950 W / < 100 W |
External auxiliary supply voltage |
230 V / 400 V (3 / N / PE) |
Cooling concept |
OptiCool |
Degree of protection: electronics / connection area (according to IEC 60529) / according to IEC 60721-3-4 |
IP54 / IP43 / 4C2, 4S2 |
Application in unprotected outdoor environments / indoor |
● / ○ |
Maximum permissible value for relative humidity (non-condensing) |
15% to 95% |
Maximum operating altitude above MSL 2000 m / 4000 m |
● / ○ |
Fresh air consumption (inverter) |
3000 m3/h |
DC connection / AC connection |
Ring terminal lug / ring terminal lug |
Display |
HMI touch display |
Communication / protocols |
Ethernet, Modbus |
DC current monitoring (Zone monitoring / String monitoring) |
○ / ○ |
SC-COM / Plant monitoring |
● / ○ (via Sunny Portal) |
Color enclosure / door / base / roof |
RAL 9016 / 9016 / 7004 / 7004 |
Guarantee: 5 / 10 / 15 / 20 years |
● / ○ / ○ / ○ |
Configurable grid management functions |
Power reduction, reactive power setpoint, dynamic grid support (e.g. LVRT) |
Certificates and approvals (more available on request) ● Standard features ○ Optional features — Not available |
EN 61000-6-2, EN 61000-6-4, EMV-Konformität, CE-Konformität, BDEW-MSRL / FGW / TR8, Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007, P.O. 12.3 / IEEE 15477) |
Type designation |
SC 900CP-10 |
Sản phẩm khác
-
SUNNY CENTRAL UP
The new Sunny Central: more power per cubic meter
-
SUNNY CENTRAL 2200 / 2475 / 2500-EV / 2750-EV / 3000-EV
The new Sunny Central: more power per cubic meter
-
SUNNY CENTRAL 1850-US / 2200-US / 2500-EV-US / 2750-EV-US
Maximum power density and integration
-
SUNNY CENTRAL 1000CP XT
The most powerful CP with an output of 1 megawatt
- Max. permissible DC voltage: 1000 V
- Nominal AC power (@ 40 °C): 1000 kVA
-
SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT
The extended CP XT: more features included
- Max. permissible DC voltage: 1000 V
- Nominal AC power (@ 50 °C): 500 kVA / 630 kVA / 720 kVA / 760 kVA
-
SUNNY CENTRAL 500CP-JP / 630CP-JP / 800CP-JP / 1000CP-JP
The perfect solution for PV power plants in Japan
- Max. input voltage: 1000 V
- Nominal AC power (@ 50 °C): 455 kVA / 630 kVA / 800 kVA / 900 kVA