SUNNY CENTRAL 1000CP XT
The most powerful CP with an output of 1 megawatt
- Max. permissible DC voltage: 1000 V
- Nominal AC power (@ 40 °C): 1000 kVA
For increased power: With its expanded functions and a peak power of 1100 kVA, the new Sunny Central 1000CP XT is now even more powerful. With its proven technology and high power density, the SC 1000CP XT completes the worldwide most successful Sunny Central CP inverter family for PV. The central inverter for outdoor use is optimized for both full nominal power in continuous operation up to 40 °C and cold temperatures as low as -40 °C. The inverter includes all grid management functions and is prepared for Q at Night, including pure reactive power management. The customized computing platform allows optimal monitoring and control.
Profitable |
Robust |
Flexible |
Versatile |
• 1 MW system power as standard • High power density for reduced transportation costs • Maximum yields with low system costs |
• Full nominal power in continuous operation at ambient temperatures up to 40 °C • Direct installation on-site, optimized for extreme climatic conditions of between −40°C and 62°C |
• Wide DC input voltage range for flexible use of various module configurations • Perfectly adjusted to temperature-- dependent behavior of PV arrays |
• All grid management functions included, prepared for Q at Night • Optimal monitoring and control thanks to customized computing platform |
Technical Data |
Sunny Central 1000CP Xt |
Input (DC)
Max. DC power (at cos φ =1) |
1122 kW |
Max. input voltage |
1000 V |
VMPP_min at IMPP < IDCmax |
596 V |
MPP voltage range (at 25°C / at 40°C / at 50°C)1) 2) |
688 V to 850 V3) / 625 V to 850 V3) / 596 V to 850 V3) |
Rated input voltage |
688 V |
Max. input current |
1635 A |
Max. DC short-circuit current |
2500 A |
Number of independent MPP inputs |
1 |
Number of DC inputs |
9 |
Output (aC)
AC power (at 25°C / at 40°C / at 50°C) |
1100 kVA / 1000 kVA / 900 kVA |
Nominal AC voltage / nominal AC voltage range |
405 V / 365 V to 465 V |
AC power frequency / range |
50 Hz, 60 Hz / 47 Hz to 63 Hz |
Rated power frequency / rated grid voltage |
50 Hz / 405 V |
Max. output current / max. total harmonic distortion |
1568 A / 0.03 |
Power factor at rated power / displacement power factor adjustable |
1 / 0.9 overexcited to 0.9 underexcited |
Feed-in phases / connection phases |
3 / 3 |
Efficiency
Max. efficiency / European efficiency / CEC efficiency |
98.7% / 98.4% / 98.5% |
Protective devices
Input-side disconnection device |
Motor-driven load-break switch |
Output-side disconnection device |
AC circuit breaker |
DC overvoltage protection |
Type I surge arrester |
Lightning protection (according to IEC 62305-1) |
Lightning Protection Level III |
Stand-alone grid detection active / passive |
● / — |
Grid monitoring |
● |
Ground fault monitoring |
○ / ○ |
Insulation monitoring |
○ |
Surge arrester for auxiliary power supply |
● |
Protection class (according to IEC 62109-1) / overvoltage category (according to IEC 60664-1) |
I / III |
General data
Dimensions (W / H / D) |
2562 / 2272 / 956 mm (101 / 89 / 38 inches) |
Weight |
1900 kg / 4300 lb |
Operating temperature range |
−25°C to 62°C / −13°F to 144°F |
Extended operating temperature range |
○ (−40°C to 62°C / −40°F to 144°F) |
Noise emission5) |
68 db(A) |
Max. self-consumption (operation)6) / self-consumption (night) |
1950 W / < 100 W |
External auxiliary supply voltage |
230 V / 400 V (3 / N / PE) |
Cooling concept |
OptiCool |
Degree of protection: electronics / connection area (according to IEC 60529) / according to IEC 60721-3-4 |
IP54 / IP43 / 4C2, 4S2 |
Application in unprotected outdoor environments / indoor |
● / ○ |
Maximum permissible value for relative humidity (non-condensing) |
15% to 95% |
Maximum operating altitude above MSL 2000 m / 4000 m |
● / ○ |
Fresh air consumption (inverter) |
3000 m3/h |
Features
DC connection / AC connection |
Ring terminal lug / ring terminal lug |
Display |
HMI touch display |
Communication / protocols |
Ethernet (optical fiber optional), Modbus |
DC current monitoring (Zone monitoring / String monitoring) |
○ / ○ |
SC-COM / Plant monitoring |
● / ○ (via Sunny Portal) |
Color enclosure / door / base / roof |
RAL 9016 / 9016 / 7004 / 7004 |
Guarantee: 5 / 10 / 15 / 20 years |
● / ○ / ○ / ○ |
Configurable grid management functions |
Power reduction, reactive power setpoint, dynamic grid support (e.g. LVRT) |
Certificates and approvals (more available on request) |
EN 61000-6-2, EN 61000-6-4, EMC-conformity, CE-conformity, BDEW-MSRL / FGW / TR8, Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007, P.O. 12.3 / IEEE 15477) |
● Standard features ○ Optional features — Not available |
|
Type designation |
SC 1000CP-10 |
Sản phẩm khác
-
SUNNY CENTRAL UP
The new Sunny Central: more power per cubic meter
-
SUNNY CENTRAL 2200 / 2475 / 2500-EV / 2750-EV / 3000-EV
The new Sunny Central: more power per cubic meter
-
SUNNY CENTRAL 1850-US / 2200-US / 2500-EV-US / 2750-EV-US
Maximum power density and integration
-
SUNNY CENTRAL 800CP XT / 850CP XT / 900CP XT
The extended CP XT: peak output up to 1 megawatt
- Max. permissible DC voltage: 1000 V
- Nominal AC power (@ 50 °C): 800 kVA / 850 kVA / 900 kVA
-
SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT
The extended CP XT: more features included
- Max. permissible DC voltage: 1000 V
- Nominal AC power (@ 50 °C): 500 kVA / 630 kVA / 720 kVA / 760 kVA
-
SUNNY CENTRAL 500CP-JP / 630CP-JP / 800CP-JP / 1000CP-JP
The perfect solution for PV power plants in Japan
- Max. input voltage: 1000 V
- Nominal AC power (@ 50 °C): 455 kVA / 630 kVA / 800 kVA / 900 kVA