The Sunny Central inverter, with 1,850 kVA or 2,200 kVA for 1,000 VDC and 2,500 kVA, 2,750 kVA or 3,000 kVA for 1,500 VDC (at 35°C), enables even more efficient PV power plant designs. The flexibility of this inverter allows for implementation with a variety of modules. The integrated power supply transformer and installation area provide an ideal environment for integration of needed customer equipment. Suitable for any outdoor climate around the globe, this new Sunny Central is equipped with OptiCool, a proven air-cooling technology that ensures smooth operation under extreme environmental conditions.


Efficient

  • Up to 4 inverters can be transported in one standard shipping container
  • Overdimensioning up to 225% is possible
  • Full power at ambient temperatures of up to 35°C

Robust

  • Intelligent air cooling system OptiCool for efficient cooling
  • Suitable for outdoor use in all climatic ambient conditions worldwide

Flexible

  • Conforms to all known grid requirements worldwide
  • Q on demand
  • Available as a single device or turnkey solution, including medium-voltage block

Easy to Use

  • Improved DC connection area
  • Connection area for customer equipment
  • Integrated voltage support for internal and external loads

Technical Data

Sunny Central 2200

Sunny Central 2475*

Input (DC)

MPP voltage range VDC (at 25 °C / at 35 °C / at 50 °C)

570 to 950 V / 800 V / 800 V

638 V to 950 V / 800 V / 800 V

Min. input voltage VDC, min / Start voltage VDC, Start

545 V / 645 V

614 V / 714 V

Max. input voltage VDC, max

1100 V

1100 V

Max. input current IDC, max (at 35°C / at 50°C)

3960 A / 3600 A

3960 A / 3600 A

Max. short-circuit current IDC, sc

6400 A

6400 A

Number of DC inputs

24 double pole fused (32 single pole fused)

Max. number of DC cables per DC input (for each polarity)

2 x 800 kcmil, 2 x 400 mm²

Integrated zone monitoring

Available DC fuse sizes (per input)

200 A, 250 A, 315 A, 350 A, 400 A, 450 A, 500 A

Output (AC)

Nominal AC power at cos φ =1 (at 35°C / at 50°C)

2200 kVA / 2000 kVA

2475 kVA / 2250 kVA

Nominal AC power at cos φ =0.8 (at 35°C / at 50°C)

1760 kW / 1600 kW

1980 kW / 1800 kW

Nominal AC current IAC, nom = Max. output current IAC, max

3300 A

3300 A

Max. total harmonic distortion

< 3% at nominal power

< 3% at nominal power

Nominal AC voltage / nominal AC voltage range1) 8)

385 V / 308 V to 462 V

434 V / 347 V to 521 V

AC power frequency / range

50 Hz / 47 Hz to 53 Hz

60 Hz / 57 Hz to 63 Hz

Min. short-circuit ratio at the AC terminals9)

> 2

Power factor at rated power / displacement power factor adjustable8) 10)

●  1 / 0.8 overexcited to 0.8 underexcited

○  1 / 0.0 overexcited to 0.0 underexcited

Efficiency

Max. efficiency2) / European efficiency2) / CEC efficiency3)

98.6% / 98.4% / 98.0%

98.6% / 98.4% / 98.0%

Protective Devices

Input-side disconnection point

DC load break switch

Output-side disconnection point

AC circuit breaker

DC overvoltage protection

Surge arrester, type I

AC overvoltage protection (optional)

Surge arrester, class I

Lightning protection (according to IEC 62305-1)

Lightning Protection Level III

Ground-fault monitoring / remote ground-fault monitoring

○ / ○

Insulation monitoring

Degree of protection: electronics / air duct / connection area (as per IEC 60529)

IP65 / IP34 / IP34

General Data

Dimensions (W / H / D)

2780 / 2318 / 1588 mm (109.4 / 91.3 / 62.5 inch)

Weight

< 3400 kg / < 7496 lb

Self-consumption (max.4) / partial load5) / average6))

< 8100 W / < 1800 W / < 2000 W

Self-consumption (standby)

< 300 W

Internal auxiliary power supply

Integrated 8.4 kVA transformer

Operating temperature range8)

−25°C to 60°C / −13°F to 140°F

Noise emission7)

67.0 dB(A)

Temperature range (standby)

−40°C to 60°C / −40°F to 140°F

Temperature range (storage)

−40°C to 70°C / −40°F to 158°F

Max. permissible value for relative humidity (condensing / non-condensing)

95% to 100% (2 month/year) / 0% to 95%

Maximum operating altitude above MSL8) 1000 m / 2000 m / 3000 m / 4000 m

●  / ○ / ○ / ○ (earlier temperature-dependent derating)

Fresh air consumption

6500 m³/h

Features

DC connection

Terminal lug on each input (without fuse)

AC connection

With busbar system (three busbars, one per line conductor)

Communication

Ethernet, Modbus Master, Modbus Slave

Communication with SMA string monitor (transmission medium)

Modbus TCP / Ethernet (FO MM, Cat-5)

Enclosure / roof color

RAL 9016 / RAL 7004

Supply transformer for external loads

○ (2.5 kVA)

Standards and directives complied with

CE, IEC / EN 62109-1, IEC / EN 62109-2, BDEW-MSRL, IEEE1547,

UL 840 Cat. IV, Arrêté du 23/04/08

EMC standards

IEC / EN 61000-6-4, IEC / EN 61000-6-2, EN 55022, IEC 62920, FCC Part 15 Class A, Cispr 11, DIN EN55011:2017

Quality standards and directives complied with

VDI/VDE 2862 page 2, DIN EN ISO 9001

●  Standard features ○ Optional * preliminary

 

 

 Type designation

SC-2200-10 

SC-2475-10 

     
     
     



  • At nominal AC voltage, nominal AC power decreases in the same proportion
  • Efficiency measured without internal power supply
  • Efficiency measured with internal power supply
  • Self-consumption at rated operation
  • Self-consumption at < 75% Pn at 25°C
  • Self-consumption averaged out from 5% to 100% Pn at 25°C
  • Sound pressure level at a distance of 10 m
  • Values apply only to Permissible values for SMA MV solutions from SMA can be found in the corresponding data sheets.
  • A short-circuit ratio of < 2 requires a special approval from SMA
  • Depending on the DC voltage

 

Technical Data

Sunny Central 2500-EV

Sunny Central 2750-EV

Sunny Central 3000-EV

Input (DC)

MPP voltage range VDC (at 25°C / at 35°C / at 50°C)

850 V to 1425 V / 1200 V /

1200 V

875 V to 1425 V / 1200 V /

1200 V

956 V to 1425 V / 1200 V /

1200 V

Min. input voltage VDC, min / Start voltage VDC, Start

778 V / 928 V

849 V / 999 V

927 V / 1077 V

Max. input voltage VDC, max

1500 V

1500 V

1500 V

Max. input current IDC, max (at 35°C / at 50°C)

3200 A / 2956 A

3200 A / 2956 A

3200 A / 2970 A

Max. short-circuit current rating

6400 A

6400 A

6400 A

Number of DC inputs

24 double pole fused (32 single pole fused) for PV

Number of DC inputs with optional DC battery coupling

18 double pole fused (36 single pole fused) for PV and 6 double pole fused for batteries

Max. number of DC cables per DC input (for each polarity)

2 x 800 kcmil, 2 x 400 mm²

Integrated zone monitoring

Available DC fuse sizes (per input)

200 A, 250 A, 315 A, 350 A, 400 A, 450 A, 500 A

Output (AC)

Nominal AC power at cos φ =1 (at 35°C / at 50°C)

2500 kVA / 2250 kVA

2750 kVA / 2500 kVA

3000 kVA / 2700 kVA

Nominal AC power at cos φ =0.8 (at 35°C / at 50°C)

2000 kW / 1800 kW

2200 kW / 2000 kW

2400 kW / 2160 kW

Nominal AC current IAC, nom = Max. output current IAC, max

2624 A

2646 A

2646 A

Max. total harmonic distortion

< 3% at nominal power

< 3% at nominal power

< 3% at nominal power

Nominal AC voltage / nominal AC voltage range1) 8)

550 V / 440 V to 660 V

600 V / 480 V to 690 V

655 V / 524 V to 721 V9)

AC power frequency

50 Hz / 47 Hz to 53 Hz

60 Hz / 57 Hz to 63 Hz

Min. short-circuit ratio at the AC terminals10)

> 2

Power factor at rated power / displacement power factor adjustable8) 11)

●  1 / 0.8 overexcited to 0.8 underexcited

○  1 / 0.0 overexcited to 0.0 underexcited

Efficiency

Max. efficiency2) / European efficiency2) / CEC efficiency3)

98.6% / 98.3% / 98.0%

98.7% / 98.5% / 98.5%

98.8% / 98.6% / 98.5%

Protective Devices

Input-side disconnection point

DC load-break switch

Output-side disconnection point

AC circuit breaker

DC overvoltage protection

Surge arrester, type I

AC overvoltage protection (optional)

Surge arrester, class I

Lightning protection (according to IEC 62305-1)

Lightning Protection Level III

Ground-fault monitoring / remote ground-fault monitoring

○ / ○

Insulation monitoring

Degree of protection: electronics / air duct / connection area

(as per IEC 60529)

IP65 / IP34 / IP34

General Data

Dimensions (W / H / D)

2780 / 2318 / 1588 mm (109.4 / 91.3 / 62.5 inch)

Weight

< 3400 kg / < 7496 lb

Self-consumption (max.4) / partial load5) / average6))

< 8100 W / < 1800 W / < 2000 W

Self-consumption (standby)

< 370 W

Internal auxiliary power supply

Integrated 8.4 kVA transformer

Operating temperature range8)

−25 to 60°C / −13 to 140°F

Noise emission7)

67.8 dB(A)

Temperature range (standby)

−40 to 60°C / −40 to 140°F

Temperature range (storage)

−40 to 70°C / −40 to 158°F

Max. permissible value for relative humidity (condensing / non-condensing)

95% to 100% (2 month / year) / 0 % to 95%

Maximum operating altitude above MSL8) 1000 m / 2000 m / 3000 m

●  / ○ / ○ (earlier temperature-dependent derating)

Fresh air consumption

6500 m³/h

Features

DC connection

Terminal lug on each input (without fuse)

AC connection

With busbar system (three busbars, one per line conductor)

Communication

Ethernet, Modbus Master, Modbus Slave

Communication with SMA string monitor (transmission medium)

Modbus TCP / Ethernet (FO MM, Cat-5)

Enclosure / roof color

RAL 9016 / RAL 7004

Supply transformer for external loads

○ (2.5 kVA)

Standards and directives complied with

CE, IEC / EN 62109-1, IEC / EN 62109-2, BDEW-MSRL, IEEE1547, Arrêté du 23/04/08

EMC standards

CISPR 11, CISPR 22,

EN55011:2017,  EN 55022,

IEC/EN 61000-6-4, IEC/EN

61000-6-2, IEC 62920,

FCC Part 15 Class A

 

CISPR 11, CISPR 22, EN55011:2017, EN 55022, IEC 62920, FCC Part 15 Class A

Quality standards and directives complied with

VDI/VDE 2862 page 2, DIN EN ISO 9001

●  Standard features ○ Optional

 

 

 

Type designation

SC-2500-EV-10

SC-2750-EV-10

SC-3000-EV-10

 

 

  • At nominal AC voltage, nominal AC power decreases in the same proportion
  • Efficiency measured without internal power supply
  • Efficiency measured with internal power supply
  • Self-consumption at rated operation
  • Self-consumption at < 75% Pn at 25°C
  • Self-consumption averaged out from 5% to 100% Pn at 35°C
  • Sound pressure level at a distance of 10 m
  • Values apply only to Permissible values for SMA MV solutions from SMA can be found in the corresponding data sheets.
  • AC voltage range can be extended to 753V for 50Hz grids only (option„Aux power supply: external“ must be selected, option “housekeeping” not combinable).
  • A short-circuit ratio of < 2 requires a special approval