Trang chủ / Sản phẩm /

GPS Module 6875 LAN

Module 6875 is a GPS Time Server in a compact aluminium housing for 35mm DIN rail mounting (DIN EN 60715 TH35).


Module 6875 is a GPS Time Server in a compact aluminium housing for 35mm DIN rail mounting (DIN EN 60715 TH35).

It consists of a GPS clock module 6875 in an extended DIN Rail housing that have an additionally implemented NTP SINEC H1 LAN Board 7273 or an NTP SINEC H1 LAN Board 7274 (2 ethernet interfaces 10/100/1000 Mbit/s autosensing, VLAN, Bonding, PRP).

Signal outputs from Module 6875 (parameterizable via hmc (hopf Management Console))

  • Serial interface COM0: RS232
    • Output of serial string, cyclic pulses, DCF77 pulse (1Hz) or digital IRIG-B signal B00x / IEEE C37.118-2005 (formerly IEEE1344-1995) / AFNOR NF S87-500
  • Serial interface COM1: RS232 or RS422 (level parameterizable via the hmc)
    • Output of serial string, cyclic pulses, DCF77 pulse (1Hz) or digital IRIG-B signal B00x / IEEE C37.118-2005 (formerly IEEE1344-1995) / AFNOR NF S87-500
  • 3x optical coupler pulse outputs (potential free)
    • Output of cyclic pulses, DCF77 pulse (1Hz) or status messages
  • 1x TTL output
    • Output of serial string, cyclic pulses, DCF77 pulse (1Hz) or digital IRIG-B signal B00x / IEEE C37.118-2005 (formerly IEEE1344-1995) / AFNOR NF S87-500
  • 1x analogue output via BNC
    • Output of DCF77 antenna simulation (77.5kHz) or analogue IRIG-B signal B12x / IEEE C37.118-2005 (formerly IEEE1344-1995) / AFNOR NF S87-500
  • Optionally available with additional:
    1x FO output for the output of a serial string, cyclic pulses, DCF77 pulse (1Hz) or digital IRIG-B signal B00x / IEEE C37.118-2005 (formerly IEEE1344-1995) / AFNOR NF S87-500

Signal outputs from board 7273 DIN-Rail (parameterizable via WEB-GUI)

  • 1x 10/100 Mbit/s autosensing via Board 7273
    • Output of the protocol for NTP/SNTP (RFC5905) and/or SINEC H1 time datagram. The full functionality of board 7273 is available.
 

Signal outputs from board 7274 DIN-Rail (parameterizable via WEB-GUI)

  • 2x 10/100/1000 Mbit/s autosensing via Board 7274
    • Output of the protocol for NTP/SNTP (RFC5905) and/or SINEC H1 time datagram. The full functionality of board 7274 is available.
  • Activation options:
    • VLAN support according to IEEE 802.1q
    • Port aggregation (NIC Bonding/Teaming) with support of IEEE 802.3ad trunks
    • Parallel Redundancy Protocol (PRP) according to IEC 62439-3

General Features

  • Different versions for various operating voltages:
    • Version with wide range power supply unit for 100-240V AC / 110-250V DC (FG6875ACxxLAN)
    • Version for 18-36V DC (FG6875DC24/xxLAN)
    • Version for 36-72V DC (FG6875DC48/xxLAN)
  • Parameterization/monitoring of module 6875 via hmc (hopf Management Console)
  • Parameterization/monitoring of board 7273 via LAN
  • Potential isolation of the GPS antenna circuit
  • Synchronisation with just one satellite possible
  • SyncOFF Timer (bridging of reception failure) providing an error-free operation even under difficult reception conditions
  • Redundant multiple test mechanism of the synchronisation signal providing a correct and leap-free signal evaluation
  • High free running accuracy
  • Maintenance-free back-up clock for three days
  • On-site firmware update via software tool possible
  • Unit completely maintenance-free
  • Options:
    • In addition 1x FO output
    • Customized hardware and software adjustments possible

Features of NTP/SINEC H1 LAN Board 7273

  • Alarming
    • SNMPv2c / SNMPv3 (MIB II, hopf Private Enterprise MIB, SNMP traps)
    • E-Mail Notification
    • SYSLOG
  • Routing for configuring static routes based on special network configuration requirements
  • SINEC H1 time datagram

Features of NTP/SINEC H1 LAN Board 7274

  • all features of NTP/SINEC H1 LAN Board 7273
  • 2 ethernet interfaces 10/100/1000 Mbit/s autosensing
  • Activation options:
    • VLAN support according to IEEE 802.1q
    • Port aggregation (NIC Bonding/Teaming) with support of IEEE 802.3ad trunks
    • Parallel Redundancy Protocol (PRP) according to IEC 62439-3

Sản phẩm khác

  • VCL-2145-LC, GPS Primary Reference Clock (PRC)

    VCL-2145-LC, GPS Primary Reference Clock (PRC)

    GPS Primary Reference Clock (PRC) provides 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits with SSM, 1.544Mbits clock outputs with high stability OCXO Holdover Clock. Rubidium Clock option available.

  • VCL-2145-SLV, PTP IEEE-1588v2 Slave Clock

    VCL-2145-SLV, PTP IEEE-1588v2 Slave Clock

    PTP Slave Clock for ToD and Frequency Synchronization - synchronizes to PTP Grandmaster to provide IRIG-B, 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits clock outputs. OCXO and Rubidium Holdover Clock options available

  • NTP100-GPS

    NTP100-GPS

    Stratum 1 NTP server locked to GPS satellites for legally traceable time-stamping.

  • NTP100-TC

    NTP100-TC

    NTP server synchronized to time code input with automatic time code source detection. Supports SMPTE (30/25/25 fps), Leitch Date Encoding Standard, IRIG-B pulse width coded (unmodulated) DC, IEEE 1344 standard, IRIG-B(1) 1 kHz Amplitude Modulated, IEEE 1344 standard

  • NTP100-OSC

    NTP100-OSC

    Stand-alone NTP server with internal precision temperature controlled crystal oscillator.

  • GMR1000

    GMR1000

    The GMR1000 is high-precision, multi-function master clocks that can act as an NTP server, PTP grandmaster, time code generator or frequency reference.

  • GMR5000

    GMR5000

    The GMR5000 is high-precision, multi-function master clocks that can act as an NTP server, PTP grandmaster, time code generator or frequency reference.

  • GPS Module 8029NTS

    GPS Module 8029NTS

    Time Server 8029NTS for DIN Rail mounting – compact and highly flexible at the same time

  • GPS Module 6870

    GPS Module 6870

    Module 6870 is a GPS clock in a compact aluminium housing for 35mm DIN rail mounting (DIN EN 60715 TH35). The module is easily clipped onto the rail via a clip based on "snap-in" mechanism.

Hotline: 0919.900.247