InfiniSolar 2-10KW Hybrid inverter
InfiniSolar is a hybrid inverter which combines solar system, AC utility, and battery power source to supply continuous power. It is suitable for remote areas where the cost of utility is too high or emergency usage when utility is not stable.
MODEL |
InfiniSolar 2KW |
InfiniSolar Plus 3KW |
InfiniSolar Plus 5KW |
InfiniSolar 3P 10KW |
InfiniSolar Plus II 3KW |
PHASE |
1-phase in/1-phase out |
1-phase in/1-phase out |
1-phase in/1-phase out |
3-phase in/3-phase out |
1-phase in/1-phase out |
Maximum PV Input Power |
2250W |
4500W |
10000W |
14850W |
4500W |
Rated Output Power |
2000W |
3000W |
5000W |
10000W |
3000W |
Maximum Charging Power |
1200 W |
1200 W |
4800 W |
9600 W |
2880 W |
GRID-TIE OPERATION |
|||||
PV INPUT (DC) |
|||||
Nominal DC Voltage / Maximum DC Voltage |
300 VDC / 350 VDC |
360 VDC / 500 VDC |
720 VDC / 900 VDC |
720 VDC / 900 VDC |
360 VDC / 500 VDC |
Start-up Voltage / Initial Feeding Voltage |
80 VDC / 120 VDC |
116 VDC / 150 VDC |
225 VDC / 250 VDC |
320 VDC / 350 VDC |
116 VDC / 150 VDC |
MPPT Voltage Range |
120 VDC~320 VDC |
250 VDC~450 VDC |
250 VDC~850 VDC |
400 VDC~800 VDC |
250 VDC~450 VDC |
Number of MPP Trackers/Max. Input Current |
1/1x15A |
1/1x18A |
2/2x10A |
2/2x18.6A |
1/1x18A |
GRID OUTPUT (AC) |
|||||
Nominal Output Voltage |
101/110/120/127 VAC |
208/220/230/240 VAC |
208/220/230/240 VAC |
230 VAC (P-N)/400 VAC (P-P) |
208/220/230/240 VAC |
Output Voltage Range |
88-127 VAC* |
184-265 VAC* |
184-265 VAC* |
184-265 VAC* per phase |
184-265 VAC* |
Nominal Output Current |
18A |
13A |
21A |
14.5A per phase |
13A |
Power Factor |
> 0.99 |
> 0.99 |
> 0.99 |
> 0.99 |
> 0.99 |
EFFICIENCY |
|||||
Maximum Conversion Efficiency (DC/AC) |
95% |
96% |
96% |
96% |
96% |
European Efficiency@Vnominal |
94% |
95% |
95% |
95% |
95% |
OFF-GRID OPERATION |
|||||
AC INPUT |
|||||
AC start-up Voltage |
60-70 VAC / 85 VAC |
120-140 VAC / 180 VAC |
120-140 VAC / 180 VAC |
120-140 VAC per phase |
120-140 VAC / 180 VAC |
Auto Restart Voltage |
180 VAC per phase |
||||
Acceptable Voltage Range |
80-130 VAC |
170-280 VAC |
170-280 VAC |
170-280 VAC per phase |
170-280 VAC |
Maximum AC Input Current |
30A |
30A |
40A |
40A |
30A |
PV INPUT (DC) |
|||||
Maximum DC Voltage |
350 VDC |
500 VDC |
900 VDC |
900 VDC |
500 VDC |
MPPT Voltage Range |
150 VDC~320 VDC |
250 VDC~450 VDC |
250 VDC~850 VDC |
400 VDC~800 VDC |
250 VDC~450 VDC |
Number of MPP Trackers/Max. Input Current |
1/1x15A |
1/1x18A |
2/2x10A |
2/2x18.6A |
1/1x18A |
BATTERY Mode Output (AC) |
|||||
Nominal Output Voltage |
101/110/120/127 VAC |
202/208/220/230/240 VAC |
202/208/220/230/240 VAC |
230 VAC (P-N)/400 VAC (P-P) |
202/208/220/230/240 VAC |
Output Waveform |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Efficiency (DC to AC) |
90% |
93% |
93% |
91% |
93% |
HYBRID OPERATION |
|||||
PV INPUT (DC) |
|||||
Nominal DC Voltage / Maximum DC Voltage |
300 VDC / 350 VDC |
360 VDC / 500 VDC |
720 VDC / 900 VDC |
720 VDC / 900 VDC |
360 VDC / 500 VDC |
Start-up Voltage / Initial Feeding Voltage |
80 VDC / 120 VDC |
116 VDC / 150 VDC |
225 VDC / 250 VDC |
320 VDC / 350 VDC |
116 VDC / 150 VDC |
MPPT Voltage Range |
150 VDC~320 VDC |
250 VDC~450 VDC |
250 VDC~850 VDC |
400 VDC~800 VDC |
250 VDC~450 VDC |
Number of MPP Trackers/Max. Input Current |
1/1x15A |
1/1x18A |
2/2x10A |
2/2x18.6A |
1/1x18A |
GRID OUTPUT (AC) |
|||||
Output Voltage Range |
88-127 VAC* |
184-264.5 VAC* |
184-264.5 VAC* |
184-264.5 VAC* per phase |
184-264.5 VAC* |
Nominal Output Current |
18A |
13A |
21A |
14.5A per phase |
13A |
AC INPUT |
|||||
AC Start-up Voltage / Auto Restart Voltage |
60-70 VAC / 85 VAC |
120-140 VAC / 180 VAC |
120-140 VAC / 180 VAC |
120-140 VAC per phase / 180 VAC per phase |
120-140 VAC / 180 VAC |
Acceptable Voltage Range |
80-130 VAC |
170-280 VAC |
170-280 VAC |
170-280 VAC per phase |
170-280 VAC |
Maximum AC Input Current |
30A |
30A |
40A |
40A |
30A |
BATTERY MODE OUTPUT (AC) |
|||||
Nominal Output Voltage |
101/110/120/127 VAC |
202/208/220/230/240 VAC |
202/208/220/230/240 VAC |
230 VAC (P-N)/400 VAC(P-P) |
202/208/220/230/240 VAC |
Efficiency (DC to AC) |
90% |
93% |
93% |
91% |
93% |
BATTERY / CHARGER |
|||||
Nominal DC Voltage |
48 VDC |
48 VDC |
48 VDC |
48 VDC |
48 VDC |
Maximum Charging Current |
Default 25A, 5A-25A (Adjustable) |
Default 25A, 5A-25A (Adjustable) |
Default 60A, 5A-100A (Adjustable) |
Default 60A, 10A-200A (Adjustable) |
Default 25A, 5A-60A (Adjustable) |
GRID OUTPUT (AC) |
|||||
Nominal Output Voltage |
101/110/120/127 VAC |
202/208/220/230/240 VAC |
202/208/220/230/240 VAC |
230 VAC (P-N)/400 VAC (P-P) |
202/208/220/230/240 VAC |
GENERAL |
|||||
PHYSICAL |
|||||
Dimension, D X W X H (mm) |
107 x 438 x 480 |
107 x 438 x 480 |
204.2 x 460x 600 |
167.5 x 500 x 622 |
107 x 438 x 480 |
Net Weight (kgs) |
15.5 |
15.5 |
29 |
45 |
15.5 |
INTERFACE |
|||||
Communication Port |
USB, RS-232 |
USB, RS-232 |
USB, RS-232 and CAN Interface |
USB, RS-232 and CAN Interface |
USB, RS-232 |
Intelligent Slot |
Optional SNMP, Modbus and AS-400 cards available |
Optional SNMP, Modbus and AS-400 cards available |
Optional SNMP, Modbus and AS-400 cards available |
Optional SNMP, Modbus and AS-400 cards available |
Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT |
|||||
Operating Humidity |
0~90% RH (Non-condensing) |
0~90% RH (Non-condensing) |
0~90% RH (Non-condensing) |
0~90% RH (Non-condensing) |
0~90% RH (Non-condensing) |
Operating Temperature |
0~40°C |
0~40°C |
-10 to 55 °C |
-10 to 55 °C |
0~40°C |
Altitude |
0~1000 m |
0~1000 m |
0~1000 m |
0~1000 m |
0~1000 m |
Sản phẩm khác
-
Sofar1100TL PV Grid-tied Inverter (Single phase)
Max 97.2% efficiency
Real time precise MPPT algorithm for max harvest
Wide input voltage operation range
-
SOFAR 1600TL PV GRID-TIED INVERTER (SINGLE PHASE)
Max 97.2% efficiency
Real time precise MPPT algorithm for max harvest
Wide input voltage operation range
-
SOFAR 2200TL PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 2700TL PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 3000TL PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 1100TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 1600TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 2200TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 2700TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 3000TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
Voltronic Power InfiniSolar E 5.5 KW
2 enhanced MPP trackers
-
Voltronic Power InfiniSolar Super 4KW
Parallel operation up to 6 units
-
Voltronic Power InfiniSolar TX 3P/3P 6KW-20KW
Built-in isolation transformer
-
Voltronic Power InfiniSolar TX-PA 30KW
Parallel operation up to 4 units
-
Voltronic Power InfiniSolar V 1K-5K
Self-consumption and feed-in to the grid
-
Voltronic Power InfiniSolar V II 1.5KW/2KW/3KW
High PV voltage range
-
SUNNY HIGHPOWER PEAK3
Customized for tomorrow, today.
Tailored to the unique needs of utilities with up to 150 kW from the pioneer of PV power plant systems
-
SUNNY HIGHPOWER PEAK1
The easy scalable solution for large PV systems
Superior power density 75 kW with only 77 kg of weight
-
SUNNY TRIPOWER 60
The efficient solution for tomorrow’s large-scale PV power plants (Formerly the MLX 60)
-
SUNNY TRIPOWER 60 Japan
The easy scalable solution for large PV systems
UP TO 150% DC/AC RATIO FOR MAXIMUM YIELD