SUNNY TRIPOWER 5000TL - 12000TL
The Three-Phase Inverter – Not Only for Your Home...
- Topology: Transformerless
- Max. DC-voltage: 1000 V
- Max. apparent AC power: 5000 VA / 6000 VA / 7000 VA / 8000 VA / 9000 VA / 10000 VA / 12000 VA
The Three-Phase Inverter – Not Only for Your Home but also perfectly suited to the design of the traditional residential PV system up to the higher power outage range. After all, with the addition of the new 10 kVA and 12 kVA versions to the portfolio, the Sunny Tripower product range covers a broad spectrum of applications. Users benefit from numerous tried-and-tested product features. Highly flexible with its proven Optiflex technology and asymmetrical multistring, it delivers maximum yields with a top efficiency rating and OptiTrac Global Peak. In addition to SMA and Sunspec Modbus communication, it also comes standard with a direct Sunny Portal connection via SMA Webconnect. Other standard features include integrated grid management functions, reactive power supply and suitability for operation with a 30 mA RCD. In summary, when it comes to system design in the 5 kW to 12 kW power classes, the Sunny Tripower is the optimum product solution – for applications ranging from use in your own home and larger PV rooftop systems to implementation of smaller-scale PV farms.
Economical |
Flexible |
Communicative |
Easy-to-Use |
• Maximum efficiency of 98.3 % • Shade management with OptiTrac Global Peak • Active temperature management with OptiCool |
• DC input voltage of up to 1,000 V • Integrated grid management functions • Reactive power supply • Module-tailored system design with Optiflex |
• SMA Webconnect • Sunny Portal communication • SMA and SunSpec Modbus communication • Simple country configuration • Multifunction relay comes standard |
• Three-phase feed-in • Cable connection without tools • SUNCLIX DC plug-in system • Integrated ESS (Electronic Solar Switch) • Easy wall mounting |
Technical Data |
Sunny Tripower 5000TL |
Sunny Tripower 12000TL |
Input (DC) |
||
Max. generator power |
9000 Wp |
18000 Wp |
Max. input voltage |
1000 V |
1000 V |
MPP voltage range / rated input voltage |
245 V to 800 V/580 V |
440 V to 800 V / 580 V |
Min. input voltage / start input voltage |
150 V / 188 V |
150 V / 188 V |
Max. input current input A / input B |
11 A / 10 A |
18 A / 10 A |
Max. short-circuit current input A / input B |
17 A / 15 A |
25 A / 15 A |
Number of independent MPP inputs / strings per MPP input |
2 / A:2; B:2 |
2 / A:2; B:2 |
Output (AC) |
||
Rated power (at 230 V, 50 Hz) |
5000 W |
12000 W |
Max. AC apparent power |
5000 VA |
12000 VA |
Nominal AC voltage |
3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
Nominal AC voltage range |
160 to 280 V |
160 V to 280 V |
AC grid frequency / range |
50 Hz, 60 Hz / -5 Hz to +5 Hz |
50 Hz, 60 Hz / -5 Hz to +5 Hz |
Rated power frequency / rated grid voltage |
50 Hz / 230 V |
50 Hz / 230 V |
Max. output current |
7.3 A |
17.4 A |
Power factor at rated power |
1 |
1 |
Adjustable displacement power factor |
0.8 overexcited to 0.8 underexcited |
0.8 overexcited to 0.8 underexcited |
Feed-in phases / connection phases |
3 / 3 |
3 / 3 |
Efficiency |
||
Max. efficiency / European efficiency |
98 % / 97.1 % |
98.3 % / 97.9 % |
Protective devices |
||
DC disconnect device |
● |
● |
Ground fault monitoring / grid monitoring |
● / ● |
● / ● |
DC reverse polarity protection / AC short-circuit current capability / galvanically isolated |
● / ● / — |
● / ● / — |
All-pole sensitive residual-current monitoring unit |
● |
● |
Protection class (according to IEC 62103)/overvoltage category (according to IEC 60664-1) |
I / III |
I / III |
General data |
||
Dimensions (W / H / D) |
470 / 730 / 240 mm (18.5 / 28.7 / 9.5 inch) |
470 / 730 / 240 mm (18.5 / 28.7 / 9.5 inch) |
Weight |
37 kg (81.6 lb) |
38 kg (812 lb) |
Operating temperature range |
-25 °C to +60 °C (-13 °F to +140 °F) |
-25 °C to +60 °C (-13 °F to +140 °F) |
Noise emission (typical) |
40 dB(A) |
40 dB(A) |
Self-consumption (at night) |
1 W |
1 W |
Topology / cooling concept |
Transformerless / Opticool |
Transformerless / Opticool |
Degree of protection (according to IEC 60529) |
IP65 |
IP65 |
Climatic category (according to IEC 60721-3-4) |
4K4H |
4K4H |
Maximum permissible value for relative humidity (non-condensing) |
100 % |
100 % |
Features |
||
DC connection / AC connection |
SUNCLIX / spring-cage terminal |
SUNCLIX / spring-cage terminal |
Display |
Graphic |
Graphic |
Interface: RS485,Modbus,Speedwire / Webconnect |
○ / ● / ● |
○ / ● / ● |
Multifunction relay / Power Control Module |
● / ○ |
● / ○ |
Guarantee: 5 / 10 / 15 / 20 years |
● / ○ / ○ / ○ |
● / ○ / ○ / ○ |
Certificates and permits (more available on request) |
AS 4777.2:2015, CE, CEI 0-21:2016, C10/11:2012, DIN EN 62109-1, EN 504381, G59/3, G83/2, IEC 61727/MEA², IEC 62109-2, NEN EN 50438, NRS 097-2-1, PPC, PPDS, RD 661/2007, RD 1699:2011, SI 4777, UTE C15-712-1, VDE0126-1-1, VDE AR-N 4105, VFR 2013, VFR 2014 |
○ |
Type designation |
STP 5000TL-20 |
STP 12000TL-20 |
Sản phẩm khác
-
InfiniSolar 2-10KW Hybrid inverter
InfiniSolar is a hybrid inverter which combines solar system, AC utility, and battery power source to supply continuous power. It is suitable for remote areas where the cost of utility is too high or emergency usage when utility is not stable.
-
Sofar1100TL PV Grid-tied Inverter (Single phase)
Max 97.2% efficiency
Real time precise MPPT algorithm for max harvest
Wide input voltage operation range
-
SOFAR 1600TL PV GRID-TIED INVERTER (SINGLE PHASE)
Max 97.2% efficiency
Real time precise MPPT algorithm for max harvest
Wide input voltage operation range
-
SOFAR 2200TL PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 2700TL PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 3000TL PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 1100TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 1600TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 2200TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 2700TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
SOFAR 3000TL-G3 PV GRID-TIED INVERTER (SINGLE PHASE)
- Max 97.2% efficiency
- Real time precise MPPT algorithm for max harvest
- Wide input voltage operation range
-
Voltronic Power InfiniSolar E 5.5 KW
2 enhanced MPP trackers
-
Voltronic Power InfiniSolar Super 4KW
Parallel operation up to 6 units
-
Voltronic Power InfiniSolar TX 3P/3P 6KW-20KW
Built-in isolation transformer
-
Voltronic Power InfiniSolar TX-PA 30KW
Parallel operation up to 4 units
-
Voltronic Power InfiniSolar V 1K-5K
Self-consumption and feed-in to the grid
-
Voltronic Power InfiniSolar V II 1.5KW/2KW/3KW
High PV voltage range
-
SUNNY HIGHPOWER PEAK3
Customized for tomorrow, today.
Tailored to the unique needs of utilities with up to 150 kW from the pioneer of PV power plant systems
-
SUNNY HIGHPOWER PEAK1
The easy scalable solution for large PV systems
Superior power density 75 kW with only 77 kg of weight
-
SUNNY TRIPOWER 60
The efficient solution for tomorrow’s large-scale PV power plants (Formerly the MLX 60)