Trang chủ / Sản phẩm /

OnCell G2111/G2151I Series

Industrial quad-band GSM/GPRS modems


Features and Benefits

  •  Quad-band GSM/GPRS 850/900/1800/1900 MHz
  •  DIN-rail mounting and wall mounting
  •  2.5 kV RMS isolation for 1 min. for all serial signals (G2151I only)
  •  LED indicators for GSM/GPRS and data transmission status
  •  Extended operating temperature from -25 to 70°C (G2111-T only)

Introduction

The OnCell G2111/G2151I Series of industrial quad-band GSM/GPRS modems are designed to transmit data and short messages (SMS) over GSM/GPRS mobile networks. The modems can be used to increase the efficiency of maintenance and communication, but do not require extensive training. In addition, the modems can be mounted on a DIN rail or wall. The OnCell G2111/G2151I Series modems accept a 12 to 48 VDC power input, making them suitable for use with a variety of field power sources.

The serial ports feature 15 kV ESD line protection to protect the products from harmful electrical discharge, and separate RS-232 and RS-422/485 interfaces are built into the OnCell G2151I, each with 2.5 kV RMS isolation protection for one minute. The two serial interfaces on the OnCell G2151I make it ideal for attaching all kinds of devices, such as stand-alone controllers, PC COM ports, and multi-dropped electric meters. In addition, the OnCell G2111-T has an extended operating temperature (-25 to 70°C) design that makes it suitable for heavy industrial use.

Cellular Interface
      - Cellular Standards: GSM, GPRS
      - Band Options: Quad-band GSM/GPRS 850 MHz / 900 MHz / 1800 MHz / 1900 MHz
      - GPRS Multi-Slot Class: 10
      - GPRS Terminal Device Class: Class B
      - GPRS Coding Schemes: CS1 to CS4
      - CSD Data Rates: Up to 14400 bps
      - Cellular Antenna Connectors: 1 SMA female
      - No. of SIMs: 1
      - SIM Control Voltage: 3 V
Serial Interface
      - No. of Ports: 1
      - Serial Standards
          All models: RS-232 (DB9 female connector)
          OnCell G2151I: RS-232/422/485 (5-pin terminal block connector)
      - ESD Protection: OnCell G2111: 15 kV
      - Isolation: OnCell G2151I: 2 kV
      - Data Bits: 8
      - Stop Bits: 1
      - Parity: None
      - Flow Control: RTS/CTS
      - Baudrate: 300 bps to 230.4 kbps
Serial Signals
      - RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND
      - RS-422: Tx+, Tx-, Rx+, Rx-, GND
      - RS-485-2w: Data+, Data-, GND
      - RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
Power Parameters
      - Input Voltage: 12 to 48 VDC
      - Power Connector: Terminal block
      - Input Current: 0.625 A @ 12 VDC, 0.16 A @ 48 VDC
Physical Characteristics
      - Housing: ABS + Polycarbonate
      - IP Rating: IP30
      - Dimensions: 27 x 123 x 79 mm (1.06 x 4.84 x 3.11 in)
      - Weight: 155 g (0.34 lb)
Environmental Limits
      - Operating Temperature
           OnCell G2111/G2151I: -20 to 55°C (-4 to 131°F)
           OnCell G2111I-T: -25 to 70°C (-13 to 158°F)
      - Storage Temperature (package included): -40 to 75°C (-40 to 167°F)
      - Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
      - Safety: UL 60950-1
      - EMC: EN 55032/24
      - EMI: CISPR 32, FCC Part 15B Class A
      - EMS
          IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
          IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
          IEC 61000-4-4 EFT: Power: 0.5 kV
          IEC 61000-4-5 Surge: Power: 1 kV
          IEC 61000-4-6 CS: 3 V
          IEC 61000-4-8 PFMF
       - Radio Frequency: FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 511
MTBF
       - Time
           OnCell G2111: 925,000 hrs
           OnCell G2111-T: 925,000 hrs
           OnCell G2151I: 864,000 hrs
       - Standards: Telcordia SR332
Warranty
       - Warranty Period: 5 years
       - Details: See www.moxa.com/warranty

 
 
OnCell G2111-T
 
 
OnCell G2151I
Cellular Standard GSM/GPRS GSM/GPRS
Band 850/900/1800/1900 MHz 850/900/1800/1900 MHz
Operating Temp. -25 to 70°C -20 to 55°C
Serial Isolation
Serial Standards RS-232/422/485 RS-232/422/485

Hotline: 0919.900.247