Module 6870 is a GPS clock in a compact aluminium housing for 35mm DIN rail mounting (DIN EN 60715 TH35). The module is easily clipped onto the rail via a clip based on "snap-in" mechanism.
Module 6870 is a GPS clock in a compact aluminium housing for 35mm DIN rail mounting (DIN EN 60715 TH35). The module is easily clipped onto the rail via a clip based on "snap-in" mechanism.
Module 6870 has two (2) individual and independent interfaces and is available in six (6) different interface versions. The interface COM0 is always implemented as RS232. The design of interface COM1 depends on the interface version of Module 6870.
The different interface versions of Module 6870 provide the below parameterizable signal outputs via the hmc (hopfManagement Console):
Interface Version 1 (RS232/RS422)
- Serial interface COM0: RS232
- Output of serial string / connection to hmc (hopf Management Console)
- Serial interface COM1: RS422
- Output of serial string (independent of COM0)
- 3x optical coupler pulse outputs (potential free)
- Output of cyclic pulses, DCF77 pulse (1Hz) or status messages
- 1x analogue output via BNC
- Output of DCF77 antenna simulation (77.5kHz)
Interface Version 2 (RS232/RS232)
- Serial interface COM0: RS232
- Output of serial string / connection to hmc (hopf Management Console)
- Serial interface COM1: RS232
- Output of serial string (independent of COM0)
- 3x optical coupler pulse outputs (potential free)
- Output of cyclic pulses, DCF77 pulse (1Hz) or status messages
- 1x analogue output via BNC
- Output of DCF77 antenna simulation (77.5kHz)
Interface Version 3 (RS232/TTY passive)
- Serial interface COM0: RS232
- Output of serial string / connection to hmc (hopf Management Console)
- Serial interface COM1: TTY passive
- Output of serial string (independent of COM0)
- 3x optical coupler pulse outputs (potential free)
- Output of cyclic pulses, DCF77 pulse (1Hz) or status messages
- 1x analogue output via BNC
- Output of DCF77 antenna simulation (77.5kHz)
Interface Version 4 (RS232/Pulse Interface in TTL Level)
- Serial interface COM0: RS232
- Output of serial string / connection to hmc (hopf Management Console)
- Serial interface COM1: TTL level (high and low active)
- Output of PPS pulse or DCF77 pulse (1Hz) in TTL level
- 3x optical coupler pulse outputs (potential free)
- Output of cyclic pulses, DCF77 pulse (1Hz) or status messages
- 1x analogue output via BNC
- Output of DCF77 antenna simulation (77.5kHz)
Interface Version 5 (RS232/RS422/IRIG-B)
- Serial interface COM0: RS232
- Output of serial string / connection to hmc (hopf Management Console)
- Serial interface COM1: RS422
- Output of serial string (independent of COM0)
- 1x output in TTL level (high active)
- Output of digital IRIG-B Signal IRIG-B B00x / IEEE C37.118-2005 (formerly IEEE 1344-1995) / AFNOR NF S87-500
- 3x optical coupler pulse outputs (potential free)
- Output of cyclic pulses, DCF77 pulse (1Hz) or status messages
- 1x analogue output via BNC
- Output of analogue IRIG-B Signal IRIG-B B12x / IEEE C37.118-2005 (formerly IEEE1344-1995) / AFNOR NF S87-500
Interface Version 6 (RS232/NGTS-Pulse)
- Serial interface COM0: RS232
- Output of serial string / connection to hmc (hopf Management Console)
- Serial interface COM1:
- Output of NGTS-pulse in RS232 level
- 3x optical coupler pulse outputs (potential free)
- Output of cyclic pulses, DCF77 pulse (1Hz) or status messages
- 1x analogue output via BNC
- Output of DCF77 antenna simulation (77.5kHz)
- Different versions for various operating voltages:
- Version with wide range power supply unit for 18-60V DC (FG6870Gxx)
- Version with wide range power supply unit for 100-240V AC / 110-250V DC (FG6870ACxx)
- Parameterization / monitoring via hmc (hopf Management Console)
- Potential isolation of the GPS antenna circuit
- Synchronisation with just one satellite possible
- SyncOFF Timer (bridging of reception failure) providing an error-free operation even under difficult reception conditions
- Redundant multiple test mechanism of the synchronisation signal providing a correct and leap-free signal evaluation
- High free running accuracy
- Maintenance-free back-up clock for three days
- Unit completely maintenance-free
- Option:
Customized hardware and software adjustments possible
Other
-
VCL PTP IEEE-1588v2 Slave Clock for ToD and Frequency Synchronization
VCL-GPS IEEE-1588v2, NTP Server (IPv4 and IPv6), provides IRIG-B, 1PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits with SSM, 1.544Mbits GPS referenced clock outputs.
-
Redundant GPS, Primary Reference Clock with IEEE-1588v2 PTP and NTP
VCL-2145 is a high-performance GPS Primary reference clock and IEEE-1588v2 PTP that provides ITU-T G.811 primary synchronization freferences which are locked to a user selected satellite source.
-
VCL-2145-LC, GPS Primary Reference Clock (PRC)
GPS Primary Reference Clock (PRC) provides 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits with SSM, 1.544Mbits clock outputs with high stability OCXO Holdover Clock. Rubidium Clock option available.
-
Primary Reference Clock with IEEE-1588v2 PTP Grandmaster and NTP
VCL-GPS-2145 Master: Provides IRIG-B, 1PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits GPS referenced clock outputs.
-
Redundant GPS, Primary Reference Clock with IEEE-1588v2 PTP Grandmaster
VCL-GPS-2145-D Grandmaster: Provides IRIG-B, 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits GPS referenced clock outputs.
-
VCL-2145-SLV, PTP IEEE-1588v2 Slave Clock
PTP Slave Clock for ToD and Frequency Synchronization - synchronizes to PTP Grandmaster to provide IRIG-B, 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits clock outputs. OCXO and Rubidium Holdover Clock options available
-
VCL-2112-SLV-LC, PTP IEEE-1588v2 Slave Clock
PTP Slave Clock for ToD and Frequency Synchronization-synchronizes to PTP Grandmaster to provide IRIG-B, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits
-
NTP100-GPS
Stratum 1 NTP server locked to GPS satellites for legally traceable time-stamping.
-
NTP100-TC
NTP server synchronized to time code input with automatic time code source detection. Supports SMPTE (30/25/25 fps), Leitch Date Encoding Standard, IRIG-B pulse width coded (unmodulated) DC, IEEE 1344 standard, IRIG-B(1) 1 kHz Amplitude Modulated, IEEE 1344 standard
-
NTP100-OSC
Stand-alone NTP server with internal precision temperature controlled crystal oscillator.
-
GMR1000
The GMR1000 is high-precision, multi-function master clocks that can act as an NTP server, PTP grandmaster, time code generator or frequency reference.
-
GMR5000
The GMR5000 is high-precision, multi-function master clocks that can act as an NTP server, PTP grandmaster, time code generator or frequency reference.
-
GPS Module 6875 LAN
Module 6875 is a GPS Time Server in a compact aluminium housing for 35mm DIN rail mounting (DIN EN 60715 TH35).
-
GPS Module 8029NTS
Time Server 8029NTS for DIN Rail mounting – compact and highly flexible at the same time
-
GPS Module 8030NTS
Compact - space-saving - highly precise - maintenance free!